P.Resources Pty Ltd.

Stench Gas the Ultimate Mine Warning Device (MWD-100)

Welcome

bus01_prod_off.gif bus01_comp_off.gif bus01_cont_off.gif

 STENCH GAS
Ethyl Mercaptan, Non-Flammable, Zero Ozone Depleting, Detectable Odor

Mine Warning Device
MWD-100 / Stench Gas / MWD-100E Ethyl Mercaptan
MWD-100 Facts
Ethyl Mercaptan provides a detectable odor at a ratio of 1 gram per 220,000 cubic feet of air.

One MWD cartridge contains 100 grams of ethyl mercaptan and should be effective in odorizing approximately 22,000,000 cubic feet of air. Individual mine test should be conducted as temperature, distance, air flow and the release rates will effect the distribution in each individual mine application.

A single MWD-100 cartridge will empty itself in ten seconds at full open valve. Tests have been made with a restrictor placed at the valve opening as follows:

(1) A 0.69mm (#71 wire drill hole) will release in 90 seconds.
(2) A 1.04mm (#59 wire drill hole) will release in 57 seconds.
(3) A 1.58mm (#52 wire drill hole) will release in 32 seconds.

 

Recent News